Message ID: 1219     Entry time: Thu Mar 26 07:39:02 2026
 Author: IC, VM, DN, MJ 
 Status: Under Process 
 Type: Shift summary 
 Category:  
 Important:
 Subject:  
 Icon:  

7h37 : mise en chauffe en remote (frigo/chiller, modulateur, laser, cyclage)

08h57 HV is ON

==> 70 MeV, F=500.031645 MHz

11h20 Beam is in the ring. recipe_recipe_LI_TL_RI_all_20260320_12_35_26.txt loaded with linac steerers adjusted

11h21 Laser Phase 54.3291 dg., Sect. Phase 256 dg., Sect. Att. 0.197 dB, I_Gun -96.9629 pC, I_Linac -144.3734 pC, I_TL -126.6061 pC RF_Ampl. 99.1184 kV, RF_Phase -59 dg.

 

Attachment 1: MRSV_Size_vs_LaserPhase.png  83 kB  Uploaded Thu Mar 26 13:51:14 2026  | Hide | Hide all | Show all
MRSV_Size_vs_LaserPhase.png
Attachment 2: HorOrbit_vs_LaserPhase.png  86 kB  Uploaded Thu Mar 26 13:51:14 2026  | Hide | Hide all | Show all
HorOrbit_vs_LaserPhase.png
Attachment 3: MRSV17h38.png  61 kB  Uploaded Thu Mar 26 17:59:55 2026  | Show | Hide all | Show all
Attachment 4: DispersionAfterLOCO20260326_16h54.png  230 kB  Uploaded Thu Mar 26 18:01:54 2026  | Hide | Hide all | Show all
DispersionAfterLOCO20260326_16h54.png
Attachment 5: 20260326_18h24_TL_Dispersion.png  76 kB  Uploaded Thu Mar 26 18:34:55 2026  | Hide | Hide all | Show all
20260326_18h24_TL_Dispersion.png