HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Commissionning Commissionning Preparation Pannes ShiftCheck
  Toutes les notes concernant les Commissionning de ThomX  Not logged in ThomX    logo
Message ID: 1164     Entry time: Fri Dec 5 14:48:46 2025
 Author: Marie Julien Hayg Sophie 
 Status:  
 Type: Shift summary 
 Category: LI | TL | LE | Ring 
 Important:
 Subject: Matching ring-TL - Recherche des bons twiss pour la TL 
 Icon:  

Programme shift : etudes matching anneau-TL - Recherche param twiss TL

Valeurs ideales TL "de Julien" : betaX = 36   betaY = 36   alphaX = -4.5   alphaY = -4.5  ( = figure of merit tres petit)

==================================================================

Mesures param twiss Q1 (quad scan Q1) - charge ~ 100 pC - 50 MeV

**** Soleno = 230 

   Compresseur = 55000
       emitX = 1.8 betaX  = 22    alphaX = -7.5
       emitY = 1.5   betaY = 7    alphaY = -1.4

   Compresseur = 45000
       emitX = 1.7   betaX = 14    alphaX = -5.5
       emitY = 1.2   betaY =  4     alphaY = -1.1

   Compresseur = 65000
       emitX = 2.3   betaX = 25    alphaX = -9
       emitY = 3.2   betaY =  7     alphaY = -1.6

   Compresseur = 95000
       emitX = 2.6   betaX = 11    alphaX = -4.
       emitY = 3.3   betaY =  9     alphaY = -2.

**** Compresseur = 95000 

Soleno = 220
       emitX = 7  betaX  = 5    alphaX = -2
       emitY = 5   betaY = 4    alphaY = -0.5

Soleno = 200
       emitX = 13  betaX  = 10    alphaX = 0.85
       emitY = 10   betaY = 35    alphaY = 0.6

Soleno = 240
       emitX = 7.4  betaX  = 18    alphaX = -4.3
       emitY = 12   betaY = 50    alphaY = -6
    SIMU matching : merit = 9

Soleno = 235
       emitX = 2.6  betaX  = 14    alphaX = -4.
       emitY = 5.4   betaY = 21    alphaY = -3.6

Soleno = 238
       emitX = 3.8  betaX  = 18    alphaX = -4.3
       emitY = 7     betaY = 34    alphaY = -5.2
    SIMU matching : merit = 24

Soleno = 245
       emitX = 8.8  betaX  = 30.4    alphaX = -6.5
       emitY = 26   betaY  = 81.6    alphaY = -8.5

    
  SIMU matching : merit = 10^-25  ==> Q1-Q7  NO backracked sortie linac: -2.02   / 4.76  / -3.176  / 2.0    / 1.62   / -4.085 / 3.98 
                                                                            Q1-Q7 BACKTRACKED                   -1.88 /  4.74  / -3.28    / 1.99  / 1.69   / -4.03   / 3.85
 Essai de stockage : cf screenshot
   

2 Remarques : 

1) 2 figures of merit tres petites ~ 10^-20 qui donnent des valeurs de TL differentes ....

    - Valeurs ideales TL "de Julien" : betaX = 36     betaY = 36      alphaX = -4.5    alphaY = -4.5 
    - Valeurs du jour :                        betaX = 30.4   betaY = 81.6   alphaX = -6.5    alphaY = -8.5
A suivre - Trouver Bonne figure of merit + minimisation emittance .... 

2) Valeurs QUADs "QP3" utilisee dans la simu RING (quads autour de l'IP) :

QP3 SIMU julien :  - 6.7 A
QP3 REEL : 
       c1_qp8 = -6.02
       c2_qp8 = -6.03
       c1_qp9 = -6.11
        c2_qp9 = -6.0

==> ~ 0.7 A de difference  - Pour les autres quads : SIMU vs REEL sont proches.

 

Attachment 1: Screenshot_from_2025-12-05_18-26-56.png  59 kB  Uploaded Fri Dec 5 19:02:56 2025  | Hide | Hide all
Screenshot_from_2025-12-05_18-26-56.png
ELOG V3.1.4-395e101