8h: mise en chauffe en remote (frigo/chiller, modulateur, laser, cyclage)
*** Programme ***
- mise en route du feedback longitudinal
- prise de donnée phase laser
Beam tuning of the injector and Ring
Measurement of the synchrotron frequency (model freq 234.21 kHz at 150 kV)
with 200 injections:
Amplitude deviation = 33.9911%
Frequency deviation = 0.48116% (269.5504 kHz)
Phase deviation = 140.4079 degrees
Average position deviation = 0.96329%
This frequency is given to Mohamed to configure the FBL.
In 1h we remeasure the frequency
Amplitude deviation = 36.5824%
Frequency deviation = 1.1559% (266.9823 kHz)
Phase deviation = 148.368 degrees
Average position deviation = 1.0323%
|