An IHM to check some of these parameters has been created (git/panneaux/StatusInfoIHM_ring_vars.py) and added to Plateforme_IHM...

Quote:

The following parameters are required for ring operations:

- At least 80pC on TL/DG/ICT.01 with std <20pC

- At least 20pC on TL/DG/ICT.02 with std <20pC

- Energy in the TL must be checked and must be 50 MeV =>  TL/BPM.02 SpX, SpY <1mm  with Std(SpX, SpY) <1mm with nominal value for TL/PS/DP.01

- Beam position must be checked on TL/DG/SST.01, TL/DG/SST.02 and TL/DG/SST.03 and be within the acceptance (see tickbox acceptance on IHM_SST).

- Beam size must be measured on TL/DG/SST.03 and be < 2mm FWHM

- Beam recipes for the LI and for the TL must be saved.

- Health check must be checked (no red entry).

- Beam centered on the last quadrupole of the transfer line.

This list will evolve as we progress in the ring commissioning.

 

 