13
|
Mon Jun 19 15:34:56 2023 |
Manar Amer | Fixed | report | lasers and optics | Other | Focal changing lens |
We are able to connect the pc soft to the lens and control its vergence and measure the value of the vergence using a method Daniele developed.
the setup is currently installed in plic room
| Manar Amer wrote: |
|
The 2 lenses are to be tested in PLIC room.
We currently have one controller for one of the lenses, Daniele is ordering the second one.
The software to drive the lens is from Optotune called "Lens Driver Controller", easy to download, already have the software on the computer ready to connect to the controler
| Manar Amer wrote: |
|
a focal changing lens was ordered for the telescope of ThomX to factor into account the change in divergence with power.
Expected to be received this week.
|
|
|
|
12
|
Mon Jun 19 15:30:19 2023 |
Manar Amer | Fixed | info | lasers and optics | Other | 33.33 & 133.33 MHz oscillator data sheet |
Adding the data sheet of both one five oscillators
133.33 is from 2017
33.33 is from 2022
|
| Attachment 1: 2022-07-08_-_Specification_Sheet_Origami-10_SN2439.pdf
|
| Attachment 2: Specification_Sheet_Origami-10_SN2440.pdf
|
|
11
|
Mon May 22 16:14:53 2023 |
Manar Amer | Fixed | report | lasers and optics | Other | Focal changing lens |
The 2 lenses are to be tested in PLIC room.
We currently have one controller for one of the lenses, Daniele is ordering the second one.
The software to drive the lens is from Optotune called "Lens Driver Controller", easy to download, already have the software on the computer ready to connect to the controler
| Manar Amer wrote: |
|
a focal changing lens was ordered for the telescope of ThomX to factor into account the change in divergence with power.
Expected to be received this week.
|
|
| Attachment 1: Optotune_Lens_Driver_4_manual.pdf
|
|
10
|
Mon May 22 15:37:38 2023 |
Manar Amer | Fixed | info | lasers and optics | ThomX igloo | Replacement Fiber for Amplifier |
2 weeks ago, Daniele changed the fiber connecting the amplifier box to the controller rack.
Then he turned the amplifier on for around 3 hours @ P=0% and 10mins @ P=10% with no errors
| Manar Amer wrote: |
|
The fiber replacement has arrived for the amplifier.
This fiber connects the head of the amplifier and the controller.
This broken fiber caused variations of the power at the output of the fiber just before the controller, causing the CRI errors in Alphanov's LAL software.
Issue should be solved when fiber is replaced.
|
|
|
9
|
Thu Apr 27 11:52:38 2023 |
Manar Amer | Fixed | info | lasers and optics | ThomX igloo | Replacement Fiber for Amplifier |
The fiber replacement has arrived for the amplifier.
This fiber connects the head of the amplifier and the controller.
This broken fiber caused variations of the power at the output of the fiber just before the controller, causing the CRI errors in Alphanov's LAL software.
Issue should be solved when fiber is replaced.
|
| Attachment 1: Bon_de_livraison_1_colis_n°04-163_THORLABS_Packing_Slip_n°MP22527053_Cde_n°0391L133124_reçu_le_26-04-2023_MANSE-CHICHE_et_DUPRAZ.pdf
|
|
8
|
Tue Mar 28 14:05:06 2023 |
Manar Amer | Fixed | report | lasers and optics | Other | Focal changing lens |
a focal changing lens was ordered for the telescope of ThomX to factor into account the change in divergence with power.
Expected to be received this week. |
| Attachment 1: Devis5081459_modifié.pdf
|
|
7
|
Wed Mar 15 18:13:19 2023 |
Manar Amer | Fixed | report | lasers and optics | ThomX igloo | New Mirrors from LMA |
Today New 16 mirrors arrived from LAM of 2 sets of 8
8 for KBox , 8 for ThomX.
The images included show only 8 but under each one there is another box so 16.
all mirrors are placed in PLIC room for the momnent. |
| Attachment 1: Miroirs_à_1031_nm-ThomX_-_KBox_Mars_2023.pdf
|
| Attachment 2: WhatsApp_Image_2023-03-15_at_6.09.53_PM(1).jpeg
|
.jpeg) |
| Attachment 3: WhatsApp_Image_2023-03-15_at_6.09.53_PM.jpeg
|
 |
|
6
|
Thu Dec 1 13:53:54 2022 |
Ronic Chiche | Fixed | info | lasers and optics | ThomX igloo | Optical lenses for the telescope |
attached is the order for the telescope spherical optical lenses |
| Attachment 1: 129594_MICRO_CONTROLE_SPECTRA_PHYSICS2.pdf
|
|
5
|
Tue Apr 5 17:58:48 2022 |
Manar Amer | Fixed | report | utilities | ThomX igloo | Fan Filter Unit |
The Clean Air Flow filtering unit installed.
The prefilters have not been changed since installation, an order for a new set of prefilters will be made to change them. !!!!!!!!!
For regular maintenance:
The Prefilters must be cleaned every 3 - 6 months, depending on their condition.
The process is to clean them by handwashing in water with a mild detergent or by using a vacuum cleaner.
Allow prefilter to dry completely before replacing. |
| Attachment 1: 268195-001_LEAC2_IOM_0217.pdf
|
|
4
|
Tue Oct 12 16:57:48 2021 |
Manar Amer | Fixed | info | utilities | ThomX igloo | Laser Safety Glasses LG1 |
3 safety glasses for ThomX cavity
LG1 - Laser Safety Glasses, Light Green Lenses, 59% Visible Light Transmission, Universal Style
|
| Attachment 1: Safty_glasses_LG1.jpg
|
 |
| Attachment 2: LG1-SpecSheet.pdf
|
| Attachment 3: Safty_glasses_LG1_specifications.png
|
 |
|
3
|
Fri Dec 18 16:01:48 2020 |
Loïc Amoudry | Fixed | info | lasers and optics | Optical room | 133.33 MHz Onefive received |
133.33 MHz Onefive left switzerland on 15th of december and arrived on 16th. |
|
2
|
Thu Nov 15 12:55:35 2018 |
Loïc Amoudry | Fixed | info | lasers and optics | Optical room | Beam viewer |
InfraRed beam viewer ordered by Viktor. |
|
1
|
Tue Nov 6 10:54:16 2018 |
Ronic Chiche | Fixed | info | detectors and electronics | Optical room | Electronics and opto-electronics devices to be ordered |
Electronics devices to be ordered :
x3 Power supplies (2x 0-30 / 5A) : 3x 333€ = 1k€
x2 Rigol DG4162 160MHz generators = 2x 1k€ = 2k€
x1 Phaselock = 4k€
Opto-electronics devices to be ordered :
x1 EOM photline-ixblue = 4k€
x5 DET100A2 photodiodes = 5x 150€ = 750€
x5 DET2A powersupply adapter = 5x 36€ = 180€
x5 PDA-C-72 power cables = 5x 18€ = 90€
x1 Calibration set @1030nm for polarimeter = 3.3k€
------------------------------------------------------------------------
Total : 15.3 k€ |