Mon Feb 24 16:28:52 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
Last Thursday (20th of February), Loïc
and Titouan realigned the stretcher CVBG
to its nominal angle and they used an interferometric
93
Wed Feb 19 17:21:28 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Powerup with 2.5ps pulses
A power up has been performed on ThomX
until 65kW intracavity power. We didn't
see any modes but stored power was really
92
Tue Feb 18 12:24:00 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
ThomX Locked with CVBGs
ThomX has been locked with a new telescope
while using compression CVBGs.
Coupling is ~50-55% and lock is stable.
91
Fri Feb 14 18:02:37 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Telescope for compressors and ThomX
CVBGs telescope is done with w ~= 1mm.
ThomX telescope is done with w
~= 2.3mm in x and y.
90
Fri Feb 14 09:26:07 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
Yesterday, Loïc put the CVBG's
back to their specified angles.
We used an interferometric technique
89
Wed Feb 12 17:43:43 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
Yesterday, Loic installed a telescope before
CVBG's to reduce the spot size on CVBG's
and reduced the incident angle 0.5-1°
88
Fri Feb 7 14:46:55 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
We installed the 2 CVBG for compression
after the amplifier.
We used an interferometric technique
87
Tue Feb 4 14:39:56 2020
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive output power
Onefive output power measured today. 3.52
mW with OD1 filter ==> ~35mW.
86
Thu Nov 28 10:40:29 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
CVBG reference and Eric Cormier calculation
The Stretcher is the "D 24-02-II",
it must be used in double path before the
amplifier injection.
85
Wed Nov 27 13:53:57 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive output power
The pump voltage has been increased few
days ago when looking for a modlock of the
laser.
84
Tue Nov 26 16:35:39 2019
Ronic Chiche
Fixed
issue
lasers and optics | detectors and electronics
Optical room
30Hz noise issue
The 30 Hz noise issue has been solved !
It came from translation stage
of P1 and/or P4.
83
Tue Nov 26 16:21:27 2019
Loïc Amoudry
Fixed
issue
vacuum
Optical room
Pneumatic valves
The pneumatic valves are now plugged on
the university air network.
The air valve is fully openned for
82
Tue Nov 26 16:11:52 2019
Ronic Chiche
Fixed
issue
mechanics
Optical room
First Lock with 2nd satge of amplifier : Motor issue ?
The 500 ms noise disapeared. We had to
disable the "power save" mode of
the smaract translation stage. AND turn OFF
81
Fri Nov 22 17:56:56 2019
Ronic Chiche
Fixed
issue
lasers and optics | detectors and electronics
Optical room
30Hz noise issue
since some days, we observe the cavity
is difficult to lock and a strange 30Hz noise
has appeared on the PZT signal which normally
80
Thu Nov 21 11:37:13 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive Origami 33MHz specs
Beam Size Onefive added
79
Wed Nov 13 15:05:18 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Amplifier output power
78
Wed Nov 13 14:44:56 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Amplifier output power
The ouput power of the ThomX amplifier
has been measured as a function of the 3rd
stage pumps current (0A is 1st and 2nd stage
77
Wed Nov 6 16:11:12 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Spherical mirrors at closest position. FSR, finesse and beam size.
The spherical mirrors are at the closest
position to get a FSR ~=33.3435 MHz. Planar
mirrors are at the largest position.
76
Tue Oct 22 09:10:45 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
First mode degeneracy on ThomX
Yesterday, we've observed the first
degeneracy on ThomX cavity at ~115 kW stored.
The shape of the stored power on the oscilloscope
75
Fri Oct 11 18:49:00 2019
Ronic Chiche
Fixed
info
detectors and electronics
Optical room
New locking scheme
Before, the locking scheme was to produce
an error signal with the PDH box, send its
output to the electronic amplifier box and