Message ID: 38     Entry time: Thu May 23 10:10:56 2019
 Author: Ronic Chiche 
 Status: Fixed 
 Type: report 
 Category: lasers and optics 
 Location: Optical room 
 Title: Finesse measurement by decay time technique 

5 Files attached:

- Note on the technique and results for the present cavity on 2019, May 21th : F ~ 18 000

- 2Tektronix scope raw data

- 2 matlab files to fit the scope raw data and extract the Finesse

Attachment 1: 2019-05-21_-_Finesse_measurement_by_decay_time_technique.docx  314 kB
Attachment 2: tek0005CH1.isf  195 kB
Attachment 3: tek0006CH1.isf  195 kB
Attachment 4: plotdata.m  1 kB  | Show | Hide all | Show all
Attachment 5: myerror.m  314 Bytes  | Show | Hide all | Show all