HOME SBOX THOMX MINICAV Utilities
SBOX orders SBOX installation SBOX commissioning SBOX control command
  Status of commissioning, report also here plots are reports.  Not logged in ELOG logo
Entry   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics 20220907_00mode.jpg20220907_00mode_diameter.jpgScreenshot_2022-09-07_0_174654.pngScreenshot_2022-09-07_2_182520.png
    Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics 
       Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics Screenshot_2022-09-08_0_133245.png
          Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics Screenshot_2022-09-08_2_144338.png
             Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics 
             Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics 
                Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics Screenshot_2022-09-09_0_120737.png
                   Reply   Locking Amplifier with Cavity , posted by Manar Amer at Optical room about lasers and optics 
Message ID: 146     Entry time: Wed Sep 7 18:58:03 2022     Reply to this: 147
 Author: Manar Amer 
 Status: Fixed 
 Type: report 
 Category: lasers and optics 
 Location: Optical room 
 Title: Locking Amplifier with Cavity  

Today we managed to observe the fundamental mode and stabilize the scan on it until we improved the alignment enough.

We see some coupling, but it is very week < 5% , We improved the alignment and the polarization, but there is still no explanation to why it is very low.

The mode shape is circular with radius = 0.89 mm at transmission point, ~ 40 cm from circular mirror.

One EOM was installed along the injection into the amplifier, we saw a drop in the power measured by the first stage monitor from ~ 8.2 mW to 7.2 mW

we improved the injection up to 7.6 mW, but it still fluctuates a lot. We need to be careful about it.

The error signal looks clean, but it is very week which is due to the weak coupling.

 

 
Attachment 1: 20220907_00mode.jpg  135 kB  | Hide | Hide all | Show all
20220907_00mode.jpg
Attachment 2: 20220907_00mode_diameter.jpg  67 kB  | Hide | Hide all | Show all
20220907_00mode_diameter.jpg
Attachment 3: Screenshot_2022-09-07_0_174654.png  36 kB  | Show | Hide all | Show all
Attachment 4: Screenshot_2022-09-07_2_182520.png  37 kB  | Hide | Hide all | Show all
Screenshot_2022-09-07_2_182520.png
ELOG V3.1.4-395e101