Amplitude GHz oscillator phase noise with PZT effect, posted by Ronic Chiche at Optical room about lasers and optics
|
Thorlabs PZT datasheet.
Reference: PC4QR
Ronic |
1GHz oscillator Frep measurement, posted by Blanc at Optical room about mechanics | lasers and optics | detectors and electronics
|
The optical spectrum of the GHz oscillator: FWHM ~ 4nm
Blanc
wrote:
a previous cavity FSR measurement was giving a center frequency around 867.5MHz. |
new smaract positions, posted by Aurélien Martens at Optical room about mechanics | software
|
| M1 and M2 at 5.1085mm and M3 and M4 at -2.9mm |
Cameras Calibration, posted by Kevin Dupraz at Optical room about lasers and optics | detectors and electronics 
|
Kevin
Dupraz wrote:
After installing cameras the actual calibration are : |
Cameras Calibration, posted by Kevin Dupraz at Optical room about lasers and optics | detectors and electronics 
|
After check a mistake has been found on the magnification. This seems to be the good calibration (feel free to cross check). The projection of the 2mm
hex is attached
|
Manip 10 12 2021 (optimization injection Burst), posted by Kevin Dupraz at Optical room about lasers and optics 
|
Manip 10/12/2021
Après recherche de la résonnance principale
- MCS miroirs plan à 5.110250mm (en derive vers les negatifs) |
Manip 14 12 2021 injection optimization (and calibration), posted by Kevin Dupraz at Optical room about lasers and optics
|
Matin :
moteurs :
M1, M2 (plans): 5.110500m |
Manip 14 12 2021 injection optimization (and calibration), posted by Kevin Dupraz at Optical room about lasers and optics
|
Après-midi :
* Optimisation de l'alignement en injection pour avoir le plus de puissance en transmission
* Optimisation (vérification) de la polarisation pour avoir le plus de couplage. |
Manip 16 12 2021 montée en puissance, posted by Kevin Dupraz at Optical room about lasers and optics
|
Matin:
* Redémarrage Tangor 4W
- couplage 15% |
Manip 16 12 2021 montée en puissance, posted by Kevin Dupraz at Optical room about lasers and optics
|
Kevin
Dupraz wrote:
Matin: |
Changements et ajout d'optiques, posted by Blanc at Optical room about lasers and optics
|
Optiques ajoutées :
- splitter 90/10 au début de la voie de réflexion, pour éjecter le flux et éviter que les lambdas ne chauffent.
- deuxième polariser pour avoir une meilleur extinction. |
Manip 17 12 2021 reprise réf nouvelle injection pour polarisation, posted by Kevin Dupraz at Optical room about lasers and optics 
|
Tangor : 4.2W
* Réalignement de l'injection suite aux modifications :
- Changement de l'ordre des waveplate maintenant : lambda/4, puis lambda/2 |
input and output power of the AOM 50MHz, posted by Blanc at Optical room about lasers and optics | detectors and electronics
|
Input power of the AOM :
150mW
output power of the AOM : |
Différence de fréquence Tangor/Lockline, posted by Blanc at Optical room about lasers and optics | detectors and electronics  
|
- On a observé que le fondamental du Tangor et celui de la Lockline n'étaient pas situés à la même fréquence.
Avec la différence de tension donnée par le piezo entre les deux et le déplacement du piezo en fonction de la tension appliquée
donnée par sa datasheet (150 V pour 20 µm), on obtient un écart de fréquence de 121 MHz [Image 1]. |
Changement cadence et duty cycle + ref cam, posted by Blanc at Optical room about lasers and optics    
|
- Prise des nouvelles ref caméras : NF{709;371} , FF{389;280} [Image 1 & 2]
- Placement d'une photodiode rapide en transmission pour voir le train d'impulsions du Tangor à travers la cavité.
- Lock du Tangor en quasi-continue, P_moy = 2W, 100 kHz. |
Problèmes Cavitée, posted by Blanc at Optical room about lasers and optics  
|
Précédentes ref pour lesquelles la manip fonctionnait :
Caméras :
709 ; 371 NF |
Données pour la baisse en cadence, posted by Blanc at Optical room about lasers and optics 7x
|
Position Cam :
692;363 NF_inj
520;193 FF_inj |
Tests et mesures lockline, posted by Blanc at Optical room about lasers and optics
|
Mesures de puissance fibres lockline :
AVANT POLISSAGE
injection premier étage : 15 mW |
Tests et mesures lockline, posted by Blanc at Optical room about lasers and optics 
|
Blanc
wrote:
Mesures de puissance fibres lockline : |
Suite Mesures de puissance lockline, posted by Blanc at Optical room about lasers and optics 
|
Changement d'AOM pour passer sur l'AOM 200 MHz.
Le schéma suivant récapitule les mesures prises.
Il y a eu une chute de la puissance en sortie de la fibre bleue de la lockline. |