<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Computer Windows update</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/20</link>
<description>
&lt;p&gt;as our computer is not only on the local network but is also connected to the internet, I did an update this morning.&lt;/p&gt;

&lt;p&gt;=&amp;gt; computer restart and remote connexion are OK.&lt;/p&gt;</description>
<pubDate>
Wed, 06 Aug 2025 10:32:56 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Changing Icepap parameters</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/19</link>
<description>
&lt;p&gt;for P4z, the nominal current has been set to 0.5A several weeks ago.&lt;br /&gt;
and today, I set it to 0.3A, like P1z, because sometime I observed a too strong steering.&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;in a command window : connect to CC client&lt;/p&gt;

			&lt;p&gt;ssh -XY kevin.dupraz@client-cc&lt;br /&gt;
			pwd : thomx2022&lt;/p&gt;

			&lt;p&gt;from this client, use the command: /usr/local/icepapcms/icepapcms&lt;/p&gt;

			&lt;p&gt;it will launch the Icepap interface.&lt;/p&gt;

			&lt;p&gt;for Mot.03 (CFP_&amp;micro;VMP20_P4z) : locator icepap-B28 =&amp;gt; icepap-B28 =&amp;gt;&amp;nbsp;CFP_&amp;micro;VMP20_P4z&lt;/p&gt;

			&lt;p&gt;for Mot.06 (CFP_&amp;micro;VMP20_P1z) : locator icepap-B17 =&amp;gt; icepap-B6 =&amp;gt;&amp;nbsp;CFP_&amp;micro;VMP20_P1z&lt;/p&gt;

			&lt;p&gt;in the &amp;quot;Motor&amp;quot; tab, one can change the nominal current (presently 0.3A for P1z and 0.7A for P4z)&lt;/p&gt;

			&lt;p&gt;you need to click on &amp;quot;Send config to board&amp;quot; &lt;strong&gt;AND &lt;/strong&gt;on &amp;quot;validate config&amp;quot; to validate your changes.&lt;/p&gt;

			&lt;p&gt;&lt;strong&gt;then motor is set to &amp;quot;OFF&amp;quot;, you have to set it &amp;quot;ON&amp;quot;&lt;/strong&gt;&lt;/p&gt;
			&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;</description>
<pubDate>
Wed, 25 Jun 2025 18:22:34 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Remote control</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/18</link>
<description>
&lt;p&gt;New password changed today:&lt;/p&gt;

&lt;p&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
login: $jehanno&lt;br /&gt;
pwd: PCfpc#123456&lt;br /&gt;
domain: pc-thomx2&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;New password:&lt;/p&gt;

			&lt;p&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
			look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
			login: $jehanno&lt;br /&gt;
			pwd: ThomX23456&lt;br /&gt;
			domain: pc-thomx2&lt;/p&gt;

			&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
				&lt;tbody&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
					&lt;/tr&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
						&lt;p&gt;Description of the present remote control of the FP-cavity instruments:&lt;/p&gt;

						&lt;ul&gt;
							&lt;li&gt;In the control room, one can access any thomX computer using this account:&lt;br /&gt;
							login : operateur.thomx&lt;br /&gt;
							pwd&amp;nbsp; : thomX202&lt;br /&gt;
							&amp;nbsp;&lt;/li&gt;
							&lt;li&gt;once logged on the computer,&lt;br /&gt;
							go to the &amp;quot;internet&amp;quot; section of the softwares&lt;br /&gt;
							and launch the Remote Deskop Control software&lt;br /&gt;
							look at the &amp;quot;1st window&amp;quot; image file to enter the remote control parameters&lt;br /&gt;
							&amp;nbsp;&lt;/li&gt;
							&lt;li&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
							look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
							login: $jehanno&lt;br /&gt;
							pwd: ThomX2345&lt;br /&gt;
							domain: pc-thomx2&lt;br /&gt;
							&amp;nbsp;&lt;/li&gt;
							&lt;li&gt;once logged to the remote computer,&lt;br /&gt;
							you can check the instruments connected to the local network : 192.168.1.1 - 255 by using the IP scanner on the desktop.&lt;br </description>
<pubDate>
Fri, 20 Jun 2025 09:31:45 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Remote control</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/17</link>
<description>
&lt;p&gt;New password:&lt;/p&gt;

&lt;p&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
login: $jehanno&lt;br /&gt;
pwd: ThomX23456&lt;br /&gt;
domain: pc-thomx2&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;Description of the present remote control of the FP-cavity instruments:&lt;/p&gt;

			&lt;ul&gt;
				&lt;li&gt;In the control room, one can access any thomX computer using this account:&lt;br /&gt;
				login : operateur.thomx&lt;br /&gt;
				pwd&amp;nbsp; : thomX202&lt;br /&gt;
				&amp;nbsp;&lt;/li&gt;
				&lt;li&gt;once logged on the computer,&lt;br /&gt;
				go to the &amp;quot;internet&amp;quot; section of the softwares&lt;br /&gt;
				and launch the Remote Deskop Control software&lt;br /&gt;
				look at the &amp;quot;1st window&amp;quot; image file to enter the remote control parameters&lt;br /&gt;
				&amp;nbsp;&lt;/li&gt;
				&lt;li&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
				look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
				login: $jehanno&lt;br /&gt;
				pwd: ThomX2345&lt;br /&gt;
				domain: pc-thomx2&lt;br /&gt;
				&amp;nbsp;&lt;/li&gt;
				&lt;li&gt;once logged to the remote computer,&lt;br /&gt;
				you can check the instruments connected to the local network : 192.168.1.1 - 255 by using the IP scanner on the desktop.&lt;br /&gt;
				see the &amp;quot;instruments&amp;quot; image to have the full list of IP adresses:&lt;br /&gt;
				192.168.1.1 : this computer has 2 ethernet cards, one on the ThomX network (192.168.229.29) and one the local instruments network (192.168.1.1)&lt;br /&gt;
				192.168.1.2 : the Netgear ethernet switch (on which all instruments are connected) address, accessible by its web server on port 80 (pwd:password)&lt;br /&gt;
				192.168.1.8 : the IP9258 power AC switch, accessible by its web server on port 80 (login: admin / pwd:12345678)&lt;br /&gt;
				&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;</description>
<pubDate>
Fri, 23 May 2025 13:07:01 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Remote control</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/16</link>
<description>
&lt;p&gt;- 192.168.1.101 : power supply for the amplifier of the 500MHz beating =&amp;gt; MANDATORY to use the proprietary software EasyPower (icon on the office) to remotely control the power supply.&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;- 192.168.1.90 : second Tektronix DPO4104 scope&lt;/p&gt;

			&lt;p&gt;- the IP9258 power AC switch, port 3 is connected to the Gentec-EO power meter power supply&lt;/p&gt;

			&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
				&lt;tbody&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
					&lt;/tr&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
						&lt;p&gt;2 remotely controlled elements have been added : both of them are connected to our ethernet switch&lt;/p&gt;

						&lt;p&gt;- 192.168.1.60 : Basler Camera, to be used and configured with the Pylon software&lt;/p&gt;

						&lt;p&gt;- 192.168.1.70 : Home-made Onefive laser peltier controller using an Arduino+ethernet shield. the software has been developped by Sebastien Pitrel from CC using Python + Arduino IDE&lt;/p&gt;

						&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
							&lt;tbody&gt;
								&lt;tr&gt;
									&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
								&lt;/tr&gt;
								&lt;tr&gt;
									&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
									&lt;p&gt;Description of the present remote control of the FP-cavity instruments:&lt;/p&gt;

									&lt;ul&gt;
										&lt;li&gt;In the control room, one can access any thomX computer using this account:&lt;br /&gt;
										login : operateur.thomx&lt;br /&gt;
										pwd&amp;nbsp; : thomX202&lt;br /&gt;
										&amp;nbsp;&lt;/li&gt;
										&lt;li&gt;once logged on the computer,&lt;br /&gt;
										go to the &amp;quot;internet&amp;quot; section of the softwares&lt;br /&gt;
										and launch the Remote Deskop Control software&lt;br /&gt;
										look at the &amp;quot;1st window&amp;</description>
<pubDate>
Wed, 02 Apr 2025 14:41:49 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, several software tools information</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/15</link>
<description>
&lt;p&gt;Atk panel for changing the phase of the CFP / 500MHz RF frequencies is in :&lt;/p&gt;

&lt;p&gt;Jive =&amp;gt; &amp;quot;devices&amp;quot; =&amp;gt; ER/CA/RAC.05-API.A01 =&amp;gt; Phase CFP 500MHz&lt;/p&gt;

&lt;p&gt;Atk panel for reading the pico-ampermeter i1-i4 :&lt;/p&gt;

&lt;p&gt;Jive =&amp;gt; &amp;quot;devices&amp;quot; =&amp;gt; XLI/OP/TMD.01 =&amp;gt; ITM to change the integration time when the pico-ampermeter is saturated.&lt;/p&gt;

&lt;p&gt;Atk panel for following the rotation of the tomographic table:&lt;/p&gt;

&lt;p&gt;Jive =&amp;gt; &amp;quot;devices&amp;quot; =&amp;gt; XLH/OP/OTA.01-RTomo =&amp;gt; Position gives the present rotation angle.&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;there are 2 news python scripts in /tmp_mnt/data/shared/commissioning/Common directrory:&lt;/p&gt;

			&lt;p&gt;- Read_Phase_Rigol_33MHz :&lt;br /&gt;
			it reads both channels phase.&lt;br /&gt;
			channel 1 is used for the ThomX synchronisation scheme of different devices.&lt;br /&gt;
			channel 2 is used specifically for triggering the RF lock with the FP-cavity.&lt;/p&gt;

			&lt;p&gt;- Write_Phase_Rigol_33MHz :&lt;br /&gt;
			first, it reads the channel 1 phase and then write the channel 2 phase with an offset (relatively to ch1) corresponding to the correct bucket.&lt;/p&gt;

			&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
				&lt;tbody&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
					&lt;/tr&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
						&lt;p&gt;- For placing the FLUO screen in the X-ray beam&lt;br /&gt;
						use Jive -&amp;gt; Device -&amp;gt; XLI/OP/FLS.01 to launch the relative AtkPanel&lt;br /&gt;
						click on &amp;quot;Inserted&amp;quot;&lt;/p&gt;

						&lt;p&gt;- For launching an X-ray trend of the photodiode placed after the FLUO screen :&lt;br /&gt;
						use a Terminal Emulator and lauch the command :&lt;br /&gt;
						&lt;strong&gt;taurustrend -r 100 /xli/op/tmd.01/i1&lt;/strong&gt; (no space between characters at the end of t</description>
<pubDate>
Thu, 20 Mar 2025 11:12:43 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, several software tools information</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/14</link>
<description>
&lt;p&gt;there are 2 news python scripts in /tmp_mnt/data/shared/commissioning/Common directrory:&lt;/p&gt;

&lt;p&gt;- Read_Phase_Rigol_33MHz :&lt;br /&gt;
it reads both channels phase.&lt;br /&gt;
channel 1 is used for the ThomX synchronisation scheme of different devices.&lt;br /&gt;
channel 2 is used specifically for triggering the RF lock with the FP-cavity.&lt;/p&gt;

&lt;p&gt;- Write_Phase_Rigol_33MHz :&lt;br /&gt;
first, it reads the channel 1 phase and then write the channel 2 phase with an offset (relatively to ch1) corresponding to the correct bucket.&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;- For placing the FLUO screen in the X-ray beam&lt;br /&gt;
			use Jive -&amp;gt; Device -&amp;gt; XLI/OP/FLS.01 to launch the relative AtkPanel&lt;br /&gt;
			click on &amp;quot;Inserted&amp;quot;&lt;/p&gt;

			&lt;p&gt;- For launching an X-ray trend of the photodiode placed after the FLUO screen :&lt;br /&gt;
			use a Terminal Emulator and lauch the command :&lt;br /&gt;
			&lt;strong&gt;taurustrend -r 100 /xli/op/tmd.01/i1&lt;/strong&gt; (no space between characters at the end of the command)&lt;br /&gt;
			the baseline should be around 200-210pA&lt;br /&gt;
			and the ratio is roughly 22 000 pA &amp;lt;=&amp;gt; 10^10 xray/s&lt;/p&gt;

			&lt;p&gt;- For moving the CFP table vertically&lt;br /&gt;
			use Jive -&amp;gt; Device -&amp;gt; OC/OP/OTA.01 to launch the relative AtkPanel&lt;br /&gt;
			the 03_Tz is the vertical motor.&lt;br /&gt;
			&lt;strong&gt;&lt;span style=&quot;color:#FF0000&quot;&gt;BE CAREFUL !!!&lt;/span&gt; &lt;/strong&gt;if you are out of the limits for this motor, you can break the bellows of the FP-cavity &lt;strong&gt;&lt;span style=&quot;color:#FF0000&quot;&gt;BE CAREFUL !!! =&amp;gt; &lt;/span&gt;&lt;/strong&gt;the safe range for this motor is +/- 3mm&lt;br /&gt;
			at the end of the day, one has to put the motor &lt;span style=&quot;color:#FF0000&quot;&gt;&lt;strong&gt;OFF &lt;/strong&gt;&lt;/span&gt;the avoid any risk of incorrect displacement.&lt;/p&gt;

			&lt;p&gt;- For scanning the CFP table vertically, you can use the Kevin Python script which moves the he</description>
<pubDate>
Tue, 18 Mar 2025 11:15:12 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, issue, cabling | software, ThomX igloo, CEM issue impacting the communication with Smaract laser motors and Alphanov laser amplifier</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/13</link>
<description>
&lt;p&gt;this morning, we saw that the injection kicker produces some CEM issues on all the machine and also on the USB communication with the PC.&lt;/p&gt;

&lt;p&gt;in that case, one needs to reset the USB communication.&lt;/p&gt;

&lt;p&gt;one can either restart the PC (which is quite long to restart all the softwares) or just unplug and replug the corresponding USB connector on the PC.&lt;/p&gt;

&lt;p&gt;on the picture,&lt;br /&gt;
- the top USB (blue) cable is for the PicolLog temperature probe measurements.&lt;br /&gt;
- the middle USB cable is for the Smaract laser motor controller&lt;br /&gt;
- the bottom USB cable is for the Alphanov laser amplifier controller&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;/p&gt;</description>
<pubDate>
Wed, 19 Feb 2025 12:44:10 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Under Process, report, software, ThomX igloo, Possible automatisation process</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/12</link>
<description>
&lt;p&gt;I found a way in Labview Signal Express to record some measurement values of a signals into a file :&lt;/p&gt;

&lt;p&gt;&amp;quot;Ajouter un &amp;eacute;tape&amp;quot; =&amp;gt; &amp;quot;charger/enregistrer des signaux&amp;quot; =&amp;gt; &amp;quot;signaux analogiques&amp;quot; =&amp;gt; &amp;quot;enregistrer au format ASCII/LVM&amp;quot;&lt;br /&gt;
and then, one selects any signal available (signals or defined measurements)&lt;/p&gt;

&lt;p&gt;presently, the file embbed only the last mean measurement of the laser PZT.&lt;br /&gt;
this file could be used to share data with other tools which could be use to correct the motor position in the ATK panel as a first step for automatisation process.&lt;/p&gt;

&lt;p&gt;for example, I wrote an Octave code which is able to display this mean value every seconds.&lt;/p&gt;</description>
<pubDate>
Mon, 17 Feb 2025 11:55:12 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Changing Icepap parameters</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/11</link>
<description>
&lt;p&gt;in a command window : connect to CC client&lt;/p&gt;

&lt;p&gt;ssh -XY kevin.dupraz@client-cc&lt;br /&gt;
pwd : thomx2022&lt;/p&gt;

&lt;p&gt;from this client, use the command: /usr/local/icepapcms/icepapcms&lt;/p&gt;

&lt;p&gt;it will launch the Icepap interface.&lt;/p&gt;

&lt;p&gt;for Mot.03 (CFP_&amp;micro;VMP20_P4z) : locator icepap-B28 =&amp;gt; icepap-B28 =&amp;gt;&amp;nbsp;CFP_&amp;micro;VMP20_P4z&lt;/p&gt;

&lt;p&gt;for Mot.06 (CFP_&amp;micro;VMP20_P1z) : locator icepap-B17 =&amp;gt; icepap-B6 =&amp;gt;&amp;nbsp;CFP_&amp;micro;VMP20_P1z&lt;/p&gt;

&lt;p&gt;in the &amp;quot;Motor&amp;quot; tab, one can change the nominal current (presently 0.3A for P1z and 0.7A for P4z)&lt;/p&gt;

&lt;p&gt;you need to click on &amp;quot;Send config to board&amp;quot; &lt;strong&gt;AND &lt;/strong&gt;on &amp;quot;validate config&amp;quot; to validate your changes.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;then motor is set to &amp;quot;OFF&amp;quot;, you have to set it &amp;quot;ON&amp;quot;&lt;/strong&gt;&lt;/p&gt;</description>
<pubDate>
Fri, 14 Feb 2025 13:32:45 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, MPS IP laser shutter command</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/10</link>
<description>
&lt;p&gt;the IP laser shutter receive a permit from both the MPS and the PSS.&lt;/p&gt;

&lt;p&gt;if the MPS permit is not granted (RED), one needs to check if the jive panel is not blocking it.&lt;/p&gt;

&lt;p&gt;go to :&lt;/p&gt;

&lt;p&gt;JIVE -&amp;gt; server -&amp;gt; PCLDO -&amp;gt; B17DO1 -&amp;gt; PLCDO -&amp;gt; ER/HF/RAC.17-API.DO1&lt;/p&gt;

&lt;p&gt;the panel shows several bits to command several devices.&lt;/p&gt;

&lt;p&gt;one needs to check the box corresponding to the line &amp;quot;Cmd Shutter FP&amp;quot;&lt;br /&gt;
&lt;strong&gt;(be careful with the other line !!!)&lt;/strong&gt;&lt;/p&gt;

&lt;p&gt;then, the MPS permit should be granted (GREEN)&lt;/p&gt;</description>
<pubDate>
Tue, 11 Feb 2025 11:08:41 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, several software tools information</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/9</link>
<description>
&lt;p&gt;- For placing the FLUO screen in the X-ray beam&lt;br /&gt;
use Jive -&amp;gt; Device -&amp;gt; XLI/OP/FLS.01 to launch the relative AtkPanel&lt;br /&gt;
click on &amp;quot;Inserted&amp;quot;&lt;/p&gt;

&lt;p&gt;- For launching an X-ray trend of the photodiode placed after the FLUO screen :&lt;br /&gt;
use a Terminal Emulator and lauch the command :&lt;br /&gt;
&lt;strong&gt;taurustrend -r 100 /xli/op/tmd.01/i1&lt;/strong&gt; (no space between characters at the end of the command)&lt;br /&gt;
the baseline should be around 200-210pA&lt;br /&gt;
and the ratio is roughly 22 000 pA &amp;lt;=&amp;gt; 10^10 xray/s&lt;/p&gt;

&lt;p&gt;- For moving the CFP table vertically&lt;br /&gt;
use Jive -&amp;gt; Device -&amp;gt; OC/OP/OTA.01 to launch the relative AtkPanel&lt;br /&gt;
the 03_Tz is the vertical motor.&lt;br /&gt;
&lt;strong&gt;&lt;span style=&quot;color:#FF0000&quot;&gt;BE CAREFUL !!!&lt;/span&gt; &lt;/strong&gt;if you are out of the limits for this motor, you can break the bellows of the FP-cavity &lt;strong&gt;&lt;span style=&quot;color:#FF0000&quot;&gt;BE CAREFUL !!! =&amp;gt; &lt;/span&gt;&lt;/strong&gt;the safe range for this motor is +/- 3mm&lt;br /&gt;
at the end of the day, one has to put the motor &lt;span style=&quot;color:#FF0000&quot;&gt;&lt;strong&gt;OFF &lt;/strong&gt;&lt;/span&gt;the avoid any risk of incorrect displacement.&lt;/p&gt;

&lt;p&gt;- For scanning the CFP table vertically, you can use the Kevin Python script which moves the hexapod table slowly in order the FPC can follow the displacement without locking losses.&lt;br /&gt;
one needs first to launch the relative AtkPanel to follow the displacement.&lt;br /&gt;
then, the script is located in /data/shared/commissioning_scripts/Xray_CFP/scan_table =&amp;gt; it launches the Spyder Python editor.&lt;br /&gt;
the variable &amp;quot;target_pos&amp;quot; is the vertical position (in mm) you want to reach with the 03_Tz motor of OTA.01&lt;br /&gt;
&lt;strong&gt;&lt;span style=&quot;color:#FF0000&quot;&gt;BE CAREFUL !!!&lt;/span&gt; &lt;/strong&gt;if you are out of the limits for this motor, you can break the bellows of the FP-cavity &lt;strong&gt;&lt;span style=&quot;color:#FF0000&quot;&gt;BE CAREFUL !!! =&amp;gt; &lt;/span&gt;&lt;/strong&gt;the safe range for this motor is +/- 3mm&lt;/p&gt;

&lt;p&gt;if one wants to plot the scan result at the end of the scan, one has to interrup</description>
<pubDate>
Thu, 12 Dec 2024 18:10:56 +0100</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Remote control</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/8</link>
<description>
&lt;p&gt;- 192.168.1.90 : second Tektronix DPO4104 scope&lt;/p&gt;

&lt;p&gt;- the IP9258 power AC switch, port 3 is connected to the Gentec-EO power meter power supply&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;2 remotely controlled elements have been added : both of them are connected to our ethernet switch&lt;/p&gt;

			&lt;p&gt;- 192.168.1.60 : Basler Camera, to be used and configured with the Pylon software&lt;/p&gt;

			&lt;p&gt;- 192.168.1.70 : Home-made Onefive laser peltier controller using an Arduino+ethernet shield. the software has been developped by Sebastien Pitrel from CC using Python + Arduino IDE&lt;/p&gt;

			&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
				&lt;tbody&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
					&lt;/tr&gt;
					&lt;tr&gt;
						&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
						&lt;p&gt;Description of the present remote control of the FP-cavity instruments:&lt;/p&gt;

						&lt;ul&gt;
							&lt;li&gt;In the control room, one can access any thomX computer using this account:&lt;br /&gt;
							login : operateur.thomx&lt;br /&gt;
							pwd&amp;nbsp; : thomX202&lt;br /&gt;
							&amp;nbsp;&lt;/li&gt;
							&lt;li&gt;once logged on the computer,&lt;br /&gt;
							go to the &amp;quot;internet&amp;quot; section of the softwares&lt;br /&gt;
							and launch the Remote Deskop Control software&lt;br /&gt;
							look at the &amp;quot;1st window&amp;quot; image file to enter the remote control parameters&lt;br /&gt;
							&amp;nbsp;&lt;/li&gt;
							&lt;li&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
							look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
							login: $jehanno&lt;br /&gt;
							pwd: ThomX2345&lt;br /&gt;
							domain: pc-thomx2&lt;br /&gt;
							&amp;nbsp;&lt;/li&gt;
							&lt;li&gt;once logged to the remote computer,&lt;br /&gt;
							you can check the instruments connected to the local network : 192.168.1.1 - 255 by using </description>
<pubDate>
Thu, 14 Sep 2023 13:48:11 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Remote control</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/7</link>
<description>
&lt;p&gt;2 remotely controlled elements have been added : both of them are connected to our ethernet switch&lt;/p&gt;

&lt;p&gt;- 192.168.1.60 : Basler Camera, to be used and configured with the Pylon software&lt;/p&gt;

&lt;p&gt;- 192.168.1.70 : Home-made Onefive laser peltier controller using an Arduino+ethernet shield. the software has been developped by Sebastien Pitrel from CC using Python + Arduino IDE&lt;/p&gt;

&lt;table align=&quot;center&quot; cellspacing=&quot;1&quot; style=&quot;border:1px solid #486090; width:98%&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#486090&quot;&gt;Ronic Chiche wrote:&lt;/td&gt;
		&lt;/tr&gt;
		&lt;tr&gt;
			&lt;td style=&quot;background-color:#FFFFB0&quot;&gt;
			&lt;p&gt;Description of the present remote control of the FP-cavity instruments:&lt;/p&gt;

			&lt;ul&gt;
				&lt;li&gt;In the control room, one can access any thomX computer using this account:&lt;br /&gt;
				login : operateur.thomx&lt;br /&gt;
				pwd&amp;nbsp; : thomX202&lt;br /&gt;
				&amp;nbsp;&lt;/li&gt;
				&lt;li&gt;once logged on the computer,&lt;br /&gt;
				go to the &amp;quot;internet&amp;quot; section of the softwares&lt;br /&gt;
				and launch the Remote Deskop Control software&lt;br /&gt;
				look at the &amp;quot;1st window&amp;quot; image file to enter the remote control parameters&lt;br /&gt;
				&amp;nbsp;&lt;/li&gt;
				&lt;li&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
				look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
				login: $jehanno&lt;br /&gt;
				pwd: ThomX2345&lt;br /&gt;
				domain: pc-thomx2&lt;br /&gt;
				&amp;nbsp;&lt;/li&gt;
				&lt;li&gt;once logged to the remote computer,&lt;br /&gt;
				you can check the instruments connected to the local network : 192.168.1.1 - 255 by using the IP scanner on the desktop.&lt;br /&gt;
				see the &amp;quot;instruments&amp;quot; image to have the full list of IP adresses:&lt;br /&gt;
				192.168.1.1 : this computer has 2 ethernet cards, one on the ThomX network (192.168.229.29) and one the local instruments network (192.168.1.1)&lt;br /&gt;
				192.168.1.2 : the Netgear ethernet switch (on which all instruments are connected) address, accessible by its web server on port 80 (pwd:password)&lt;br /&gt;
				192.168.1.8 : the IP9258 power A</description>
<pubDate>
Wed, 05 Jul 2023 17:00:58 +0200</pubDate>
</item>
<item>
<title>Ronic Chiche, Fixed, info, software, ThomX igloo, Remote control</title>
<link>http://elog-ijclab-in2p3-fr.lal.in2p3.fr:8087/THOMX+control+command/6</link>
<description>
&lt;p&gt;Description of the present remote control of the FP-cavity instruments:&lt;/p&gt;

&lt;ul&gt;
	&lt;li&gt;In the control room, one can access any thomX computer using this account:&lt;br /&gt;
	login : operateur.thomx&lt;br /&gt;
	pwd&amp;nbsp; : thomX202&lt;br /&gt;
	&amp;nbsp;&lt;/li&gt;
	&lt;li&gt;once logged on the computer,&lt;br /&gt;
	go to the &amp;quot;internet&amp;quot; section of the softwares&lt;br /&gt;
	and launch the Remote Deskop Control software&lt;br /&gt;
	look at the &amp;quot;1st window&amp;quot; image file to enter the remote control parameters&lt;br /&gt;
	&amp;nbsp;&lt;/li&gt;
	&lt;li&gt;once connected to the remote computer (192.168.229.29)&lt;br /&gt;
	look at the &amp;quot;2nd window&amp;quot; image file to enter the account information:&lt;br /&gt;
	login: $jehanno&lt;br /&gt;
	pwd: ThomX2345&lt;br /&gt;
	domain: pc-thomx2&lt;br /&gt;
	&amp;nbsp;&lt;/li&gt;
	&lt;li&gt;once logged to the remote computer,&lt;br /&gt;
	you can check the instruments connected to the local network : 192.168.1.1 - 255 by using the IP scanner on the desktop.&lt;br /&gt;
	see the &amp;quot;instruments&amp;quot; image to have the full list of IP adresses:&lt;br /&gt;
	192.168.1.1 : this computer has 2 ethernet cards, one on the ThomX network (192.168.229.29) and one the local instruments network (192.168.1.1)&lt;br /&gt;
	192.168.1.2 : the Netgear ethernet switch (on which all instruments are connected) address, accessible by its web server on port 80 (pwd:password)&lt;br /&gt;
	192.168.1.8 : the IP9258 power AC switch, accessible by its web server on port 80 (login: admin / pwd:12345678)&lt;br /&gt;
	&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; port 1 is connected to the Onefive Smaract motors (Frep and CEP)&lt;br /&gt;
	&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; port 2 is connected to the Laselock&lt;br /&gt;
	192.168.1.10: Smaract motors controller, accessible by its dedicated Precision Tool Commander software directly on its ethernet address&lt;br /&gt;
	192.168.1.20: Laselock controller, accessible by its dedicated Kangoo software on the </description>