Message ID: 43     Entry time: Tue Jun 18 20:44:34 2019
 Author: Huan Wang 
 Status: Fixed 
 Type: info 
 Category: lasers and optics 
 Location: Optical room 
 Title: telescope for Koheras 

telescope of Koheras is removed, information record here:

- distance between collimator edge and -50 lens mount edge is 14.7cm,

- distance between another edge of -50 lens mount and +250 lens mount edge is 14.3cm,

- distance between another edge of +250 lens mount and edge of bread board is 25cm.

Attachment 1: 2019.06.18_telescope_of_Koheras.jpg  178 kB  | Hide | Hide all
2019.06.18_telescope_of_Koheras.jpg