Message ID: 393     Entry time: Wed Jan 22 15:32:53 2025
 Author: Ronic Chiche 
 Status: Fixed 
 Type: info 
 Category: mechanics | lasers and optics | vacuum 
 Location: ThomX igloo 
 Title: correlations between vacuum gauges and lock losses @ 20Hz 

the machine people saw a correlation between BPM jumps and vacuum gauges peaks related to breakdowns in the beam pipe.

these breakdowns could produce some accoustic noise which could be related to our lock losses.

=> we tried to do a corrrelation between our lock losses and the vacuum gauge peaks => WE DON'T SEE any correlation !!!