Message ID: 35     Entry time: Thu Apr 18 16:17:53 2019
 Author: Loïc Amoudry 
 Status: Fixed 
 Type: issue 
 Category: lasers and optics 
 Location: Optical room 
 Title: 33MHz Onefive power overtime decrease 

Power of the 33MHz Onfive decreases over time. Have to pay attention to that.
Note that air dryers have never been stopped.

10th april 2018: ~40mW (first picture, 10dB filter)
25th september 2018: ~36mW (second picture, 10dB filter)
16th april 2019: ~29mW (third picture, no filter)
 

Attachment 1: 180410_power_33mhz_1jours.PNG  91 kB  | Show | Hide all | Show all
Attachment 2: 180925_Power.JPG  201 kB  | Show | Hide all | Show all
Attachment 3: 190416_power_ouput_Onefive.PNG  147 kB  | Hide | Hide all | Show all
190416_power_ouput_Onefive.PNG