Message ID: 262     Entry time: Fri Sep 15 19:13:44 2023
 Author: Ronic Chiche 
 Status: Fixed 
 Type: info 
 Category: lasers and optics 
 Location: ThomX igloo 
 Title: drift calculation for the SMA100A 

the goal is to estimate what could be the frequency drift at 500MHz for the SMA100A: see phase noise datasheet in attachement

Sphi(f) = FFT ( Rphi(T) ) = FFT ( < Phi(t) Phi(t+T) > )

at low frequency, Sphi(f) ~ A / (f^n) = A*(2pi)^n / (i2pi*f)^n => Rphi(T) = A*(2pi)^n*T^(n-1) / (n-1)!

for the SMA100A : n ~ 2 and A =10^-7 at f0=1GHz with B22 option

=> Rphi(T) ~ 4e-6*T

 

 

Attachment 1: Capture1.PNG  145 kB  | Show | Hide all | Show all
Attachment 2: Capture2.PNG  155 kB  | Hide | Hide all | Show all
Capture2.PNG