Message ID: 21     Entry time: Tue Mar 26 18:26:32 2019
 Author: Loïc Amoudry 
 Status: Fixed 
 Type: report 
 Category: lasers and optics 
 Location: Optical room 
 Title: Check of mirrors and coating directions 

Direction of HR face of P1 and P4 have been checked, there was no problem. The mirrors are in the good direction and the coating is on the good face.

Once P1 and P4 outside of the cavity, we checked the coating position by sending the HeNe laser with an angle. There was two reflections and the most intense was the one closer to the normal to the mirror.

On P4 we noticed a spot which seems to be in the coating (does not move while sending nitrogen).

Attachment 1: ThomX_P4.jpg  104 kB  | Show | Show all