Message ID: 16     Entry time: Thu Feb 14 18:20:52 2019
 Author: Loïc Amoudry 
 Status: Fixed 
 Type: report 
 Category: mechanics | lasers and optics 
 Location: Optical room 
 Title: Basic alignment & alignment motors check 

14/02/19: The 4 motors but Mby control works. Mby motor home does not bring it to its "middle" position but to the end of its range. Issue circumvented using the higher rights software.

The beam is now going through the cavity windows (from P1 to S2).