HOME SBOX THOMX MINICAV Utilities
SBOX orders SBOX installation SBOX commissioning SBOX control command
  Status of commissioning, report also here plots are reports.  Not logged in ELOG logo
Entry   2nd stage amplifier issue, posted by Ronic Chiche at Optical room about lasers and optics 
    Reply   2nd stage amplifier issue, posted by Ronic Chiche at Optical room about lasers and optics 
       Reply   2nd stage amplifier issue, posted by Ronic Chiche at Optical room about lasers and optics 
Message ID: 34     Entry time: Thu Dec 12 11:49:05 2019     In reply to: 33     Reply to this: 35
 Author: Ronic Chiche 
 Status: Fixed 
 Type: issue 
 Category: lasers and optics 
 Location: Optical room 
 Title: 2nd stage amplifier issue 

Last time, we switched ON directly the 2nd stage at 6A without increasing/decrinsing slowly the current.
today, we switched ON the chiller, switched ON the 1st stage, switch ON the power supply of the 2nd stage at 0A and then we increased slowly the current until 6A... and the problem disappeared.

ARonic Chiche wrote:

the 2nd stage amplifier needed several hours (4-5h) to reach its nominal power (we look at photodiode level on a scope), instead of the awaited 30 minutes.

could it come from the probable spectrum shifting of the OneFive laser ?
(the power coming from the CVBG, coupled to the fiber, is lower than expected).

 

ELOG V3.1.4-395e101