HOME SBOX THOMX MINICAV Utilities
SBOX orders SBOX installation SBOX commissioning SBOX control command
  Status of commissioning, report also here plots are reports.  Not logged in ELOG logo
Entry   Power storage In Cavity, posted by Manar Amer at Optical room about lasers and optics 
    Reply   Power storage In Cavity, posted by Manar Amer at Optical room about lasers and optics Transmission_after_S2.jpg
       Reply   Power storage In Cavity, posted by Manar Amer at Optical room about lasers and optics 
          Reply   Power storage In Cavity, posted by Manar Amer at Optical room about lasers and optics 00mode_higer.jpg00mode_Removed_higer.jpg
             Reply   liPower storage In Cavity, posted by Manar Amer at Optical room about lasers and optics Screenshot_2022-09-13_0_184445.png
                Reply   Power storage In Cavity, posted by Manar Amer at Optical room about lasers and optics High_Finesse_sign_on_transmission_.jpgScreenshot_2022-09-14_0_161520.png
                   Reply   Power storage In Cavity, posted by Manar Amer at Optical room about lasers and optics Screenshot_2022-09-14_0_161520.png
Message ID: 155     Entry time: Fri Sep 9 15:47:46 2022     In reply to: 154     Reply to this: 158
 Author: Manar Amer 
 Status: Fixed 
 Type: report 
 Category: lasers and optics 
 Location: Optical room 
 Title: Power storage In Cavity 

At transmission power of 42 mW, coupling 60%, we see fundamental mode with a degeneracy

The D-shape motors were moved to a position 2 000 000 steps (in theory they should be the max position)

but no change appeared on the 00 mode or the higher order mode.

We will break the vacuum and check the position of the D-shaped mirrors.

Manar Amer wrote:

We start of power output from amplifier of 1W with only the first and second stage on then we start with the third stage power increase,

Note: when changing the current on the third stage 4 diodes, better to do it step by step for each one with a step of ~ 0.5 A

  •  

Amplifier output current (A)

for four diodes

Power Output (W)

Transmitted power (MW)

 

0 , 0 , 0 ,  0 ~ 1 2.3
1 , 1 , 1 , 1 / 11.0
1.5 , 1.3, 1 , 1 / 35
1.5 , 1.5 , 1 , 1 / 42.16
   

 

  • we placed at the transmission point a splitter the transmitted power before was 35 mW after placing it we had 26 mW
    • 97 % transmission , 3% reflected which goes to the beam profiler

 

  • We see degeneracy modes at the last step of 42.16 mW , so we started to test the D-shaped mirrors
    • the full range of the motors is 50.8 mm
    • each step =  30 nm , 30 000 steps = 1 mm

 