Entry   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics 
    Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics Focal_length_divergence_method.pdfBeam_Profile_at_high_power_.jpgSBOX_CELIA_AMPLIFIER_Divergence_measurement.pdf
       Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics 20220823_setup.jpg
          Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics Capture.PNGTelescope_AMPLI_CELIA_1.xml
             Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics Ampli_Celia_2.3mrad_divergence_New_Telescope.jpgBeam_waist_at_injection_image.jpg
                Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics 20220905_Telescope_lense_placement.jpg
                   Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics 
       Reply   Telescope / amplifier output, posted by Manar Amer at Optical room about lasers and optics Beam_Profile_Fit_using_gaussian_Beam.jpgBeam_Profile_Fit_using_gaussian_Beam.xml
Message ID: 134     Entry time: Mon Aug 22 18:38:03 2022     In reply to: 133     Reply to this: 136   141
 Author: Manar Amer 
 Status: Fixed 
 Type: report 
 Category: lasers and optics 
 Location: Optical room 
 Title: Telescope / amplifier output 

Beam divergence was measured using a method called  "Focal Length Divergence Measurement Method"

Where a lens of a known focal length is placed on the beam path and the beam waist is measured at the focal distance using a beam profiler.

We ramped the power up to 10 W

for a focal length = 400 mm,

we measured a FWHM = 2.1 mm,

corresponding to a divergence = 4.45 mrad  (edit : wrong software use)

for comparison, we measured the FWHM 8.1 mm  @ 1.55 m and extracted the divergence directly 4.46 mrad  (edit : this measurement is wrong - wrong use of the software)

Note: better to use a lens of a focal lens higher than 100 mm (to reduce the error in the distance measured)

 

 

 

Manar Amer wrote:

The previous Sbox telescope was dismantled and the mechanical components cleaned.

its lenses are still in the mounts, it looks that two of them are spherical and two are cylindrical

2 are -100 mm and 2 are +150 mm, there is also a box containing fused silica lenses that could be used.

Note: at high power use only fused silica lenses not BK7 type

 

 

 

Attachment 1: Focal_length_divergence_method.pdf  317 kB
Attachment 2: Beam_Profile_at_high_power_.jpg  43 kB  | Show | Hide all | Show all
Attachment 3: SBOX_CELIA_AMPLIFIER_Divergence_measurement.pdf  240 kB  Uploaded Mon Aug 22 19:46:38 2022