Entry   Couplage and CEP, posted by Blanc at Optical room about lasers and optics Fit_Delta_en_fonction_de_la_CEP_Preamp.pngFit_Delta_en_fonction_de_la_CEP_Preamp&Etage1Lockline.png
    Reply   Couplage and CEP, posted by Blanc at Optical room about lasers and optics Fit_Delta_en_fonction_de_la_CEP_Preamp.pngFit_Delta_en_fonction_de_la_CEP_Preamp&Etage1Lockline.png
       Reply   Couplage and CEP, posted by Blanc at Optical room about lasers and optics Fit_Gain_en_fonction_de_la_CEP_Preamp.pngFit_Gain_en_fonction_de_la_CEP_Preamp&Etage1Lockline.png
Message ID: 85     Entry time: Mon Apr 24 18:41:27 2023     Reply to this: 86
 Author: Blanc 
 Status: Fixed 
 Type: info 
 Category: lasers and optics 
 Location: Optical room 
 Title: Couplage and CEP 

Pour avoir une idée du couplage en fonction de la CEP, j'ai pris 11 séries de 10 mesures de l'intensité réfléchie en changeant la CEP avec des AOM.

J'ai pu calculé chaque Δ = (I_Delock-I_lock)/I_Delock = C(1-|R|²) ainsi que leurs déviation standard, puis j'ai fait une moyenne sur les 10 mesures pour avoir un Δ et une barre d'erreur pour chaque Fréquence.

Enfin j'ai pu faire un fit de ces Δ en prenant en compte les barres d'erreur, et cela donne les courbes ci-dessous.

La première courbe est pour le preamp uniquement, et la deuxième pour le preamp+le premier étage de la lockline.

Attachment 1: Fit_Delta_en_fonction_de_la_CEP_Preamp.png  42 kB  | Hide | Hide all
Fit_Delta_en_fonction_de_la_CEP_Preamp.png
Attachment 2: Fit_Delta_en_fonction_de_la_CEP_Preamp&Etage1Lockline.png  47 kB  | Hide | Hide all
Fit_Delta_en_fonction_de_la_CEP_Preamp&Etage1Lockline.png