Entry   Mesures de Polarisation, posted by Blanc at Optical room about lasers and optics Paramètres_de_Stokes.pngDOP_DOLP_DOCP.pngPhase_Ellipticité_Êta.pngEllipse_polarisation_cavité.png
    Reply   Mesures de Polarisation, posted by Blanc at Optical room about lasers and optics Ellipse_Polarization_CAVITY.png
Message ID: 66     Entry time: Mon Jan 30 14:39:52 2023     Reply to this: 67
 Author: Blanc 
 Status: Fixed 
 Type: info 
 Category: lasers and optics 
 Location: Optical room 
 Title: Mesures de Polarisation 

En récupérant la transmission du miroir M3 sphérique sortant de la cavité, on a pu faire une mesure de polarisation de la cavité. (Cf courbes ci-dessous)

La moyenne pour chaque courbe donne :

S0 = 1.0058 ; S1 = 0.4643 ; S2 = 0.0488 ; S3 = 0.8913

DOP = 1.0062 ; DOLP = 0.4669 ; DOCP = 0.8913

Phase = 86.8705° ; Ellipticité = 0.6076 ; Êta = 2.9962

Température de la tête du polarimètre : 39.9815

Par reconstruction, on obtient l'ellipse donnée en bleu ci-dessous.